Parameter/Model | VHP-444 | VHP-445 | VHP-446 | VHP-554 | VHP-555 |
Effective hot zone size W×H×L (mm) | 400×400×400 | 500×500×600 | 400×400×600 | 500×500×400 | 500×500×500 |
Heating Power (kW) | Determine the power value based on the maximum temperature of the ordered equipment | ||||
Max. temperature (°C) | 2000/2400/2600 | ||||
Loading pressure (T) | 30-200 | 30-200 | 30-200 | 30-300 | 30-300 |
Temperature Uniformity (°C) | ±5 | ±5 | ±5 | ±5 | ±5 |
Vacuum degree (Pa) | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 |
Pressure Increasing Rate (Pa/h) | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 |
≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 | |
Quantity pressing plate | Single/Multi | Single/Multi | Single/Multi | Single/Multi | Single/Multi |
Parallelism of upper and lower plate (mm) | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 |
Pressure accuracy | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% |
full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | |
Displacement accuracy (mm) | H±0.05 | H±0.05 | H±0.05 | H±0.05 | H±0.05 |
Gas cooling pressure (bar) | 2-10 | 2-10 | 2-10 | 2-10 | 2-10 |
Parameter/Model | VHP-556 | VHP-666 (A/B) | VHP-777 | VHP-888 | VHP-9910 |
Effective hot zone size W×H×L (mm) | 500×500×600 | 600×600×600 | 700×700×700 | 800×800×800 | 900×900×1000 |
Heating Power (kW) | Determine the power value based on the maximum temperature of the ordered equipment | ||||
Max. temperature (°C) | 2000/2400/2600 | ||||
Loading pressure (T) | 30-300 | 50-400 | 50-500 | 100-700 | 200-800 |
Temperature Uniformity (°C) | ±5 | ±5 | ±5 | ±5 | ±5 |
Vacuum degree (Pa) | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 |
Pressure Increasing Rate (Pa/h) | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 |
≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 | |
Quantity pressing plate | Single/Multi | Single/Multi | Single/Multi | Single/Multi | Single/Multi |
Parallelism of upper and lower plate (mm) | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 |
Pressure accuracy | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% |
full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | |
Displacement accuracy (mm) | H±0.05 | H±0.05 | H±0.05 | H±0.05 | H±0.05 |
Gas cooling pressure (bar) | 2-10 | 2-10 | 2-10 | 2-10 | 2-10 |
Parameter/Model | VHP-101010 | VHP-121206 | VHP-131314 | VHP-141412 |
Effective hot zone size W×H×L (mm) | 1000×1000×1000 | 1200×1200×600 | 1300×1300×1400 | 1400×1400×1200 |
Heating Power (kW) | Determine the power value based on the maximum temperature of the ordered equipment | |||
Max. temperature (°C) | 2000/2400/2600 | |||
Loading pressure (T) | 200-1000 | 300-1500 | 300-2000 | 300-2000 |
Temperature Uniformity (°C) | ±5 | ±5 | ±5 | ±5 |
Vacuum degree (Pa) | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 |
Pressure Increasing Rate (Pa/h) | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 |
≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 | |
Quantity pressing plate | Single/Multi | Single/Multi | Single/Multi | Single/Multi |
Parallelism of upper and lower plate (mm) | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 |
Pressure accuracy | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% |
full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | |
Displacement accuracy (mm) | H±0.05 | H±0.05 | H±0.05 | H±0.05 |
Gas cooling pressure (bar) | 2-10 | 2-10 | 2-10 | 2-10 |